Patient K, 60 years old. Saccular aneurysm of the basilar artery bifurcation (marked with a red arrow) with a diverticulum (the rupture site, blue arrow) (Fig. A). The patient was admitted on day 3 of the illness with massive subarachnoid hemorrhage due to aneurysm rupture and was operated on endovascularly on day 5. 45 minutes before surgery the patient received BRILINTA™ 180 mg.
Intraoperatively, 5000 U of heparin. Given the complex structure of the aneurysm and its wide neck (6.5 mm), in order to preserve the patency of both posterior cerebral arteries and the basilar artery, two protective ACCLINO® flex plus stents (Acandis®) were first implanted from the P1 segments of both posterior cerebral arteries into the basilar artery (Y-stenting). Red arrows mark the proximal and distal ends of the first stent, white arrows – of the second, and the yellow arrow – the distal marker of the Headway17 microcatheter (Microvention Terumo), which was advanced into the aneurysm cavity through the stent cells at their crossing (Fig. B). Framing was performed with an AXIUM™ PRIME FRAME coil (Medtronic) (Fig. C). The aneurysm cavity was filled with 4 ED COIL∞10 Soft microcoils (Kaneka) until a coil conglomerate of metallic density was formed.
The aneurysm was totally and reconstructively excluded from the circulation (Fig. D). There were no complications. The patient was discharged 2 weeks after surgery in satisfactory condition.